Native assistant research

The text-capacity chart shows the measured stock and patched limits against the existing buffer.

The stock assistant path transports phone-produced instructions to a native watch UI. The phone-side serializer, BES-side decoder, and Bluetooth framing all preserve strings longer than 300 characters. The observed truncation occurs in the main firmware's UTF-8 to UTF-16 conversion.

Verified handler

The relevant handler starts near runtime 0x0813024c. For instruction/message type 8, it clears an 800-byte inline buffer and then passes capacity 300 to the converter at runtime 0x081f88c8:

08130344  mov.w r2, #800      ; memset size in bytes
08130348  mov   r0, r7
0813034a  bl    memset
0813034e  movs  r3, #42       ; replacement character '*'
08130350  mov.w r2, #300      ; UTF-16 capacity
08130354  mov   r1, r7
08130356  ldr   r0, [r6, #4]  ; UTF-8 source
08130358  bl    0x081f88c8    ; UTF-8 -> UTF-16

The converter reserves one code unit for a NUL terminator. Capacity 300 therefore produces at most 299 visible UTF-16 code units.

Object layout

Observed fields relative to the containing object:

Offset Meaning
+0x2b80 State flag
+0x2b82 Converted/displayed length
+0x2b84 Additional flag
+0x2b86 Start of 800-byte inline text buffer

The object size is 0x2ea8 bytes. The text buffer ends immediately before the object boundary; it cannot safely hold more than 400 UTF-16 code units.

Conservative capacity patch

At component file offset 0x130350:

old instruction bytes: 4f f4 96 72   ; mov.w r2, #300
new instruction bytes: 4f f4 c8 72   ; mov.w r2, #400

Only byte 0x130352 changes. The safe maximum becomes 399 visible code units. Setting a larger immediate would write beyond the object and is not a valid way to remove the limit.

Going beyond 399 in one response requires either enlarging every dependent object layout or allocating a separate dynamic buffer and redirecting all producers and consumers. That work is not complete.